
HSP1P 16 AC25 2P W-SCT | HSP1P 16 AC50 2P W-SCT | HSP1P 16 AC25 3P W-SCT | HSP1P 16 AC50 3P W-SCT | HSP1P 16 DC25 3P W-SCT | SP1P 16 DC50 3P W-SCT | HSP1P 16 DC250 3P W-SCT | HSP1P 16 AC130 3P W-SCT | HSP1P 16 AC250 3P W-SCT | HSP1P 16 AC250 4P W-SCT | HSP1P 16 AC415 4P W-SCT | HSP1P 16 AC500 4P W-SCT | HSP1P 16 AC690 4P W-SCT | HSP1P 16 AC250 5P W-SCT | HSP1P 16 AC415 5P W-SCT | HSP1P 16 AC500 5P W-SCT | HSP1P 16 AC690 5P W-SCT
Ex 16A Wandsteckdosen
2-polig | 3-polig | 4-polig | 5-polig
ATEX-Kennzeichnung
II 2 G Ex db eb IIC T5 Gb
II 2 D Ex tb IIIC T80 °C Db
Technische Daten
Downloads

Ein Vergleich mit Marken aus Deutschland, Italien und Kroatien ergab einen durchschnittlichen Preisunterschied von 30 Prozent, ohne dass dabei ein Unterschied in der Verarbeitungsqualität erkennbar war.

Wir füllen unseren Lagerbestand laufend auf, damit die beliebtesten Varianten sofort verfügbar sind.

Wir entwickeln und fertigen Steckdosen-Sets und Verteilerkästen für Ex-Bereiche, die genau auf die Anforderungen der jeweiligen Installation zugeschnitten sind.

Sind unsere Produkte von hoher Qualität? Vereinbare einen Termin in unserem Vorführzentrum und vergleiche sie mit den Lösungen anderer Anbieter.

Ehemalige Buchsen und Stecker
Wichtigste elektrische Parameter
POLES | AC/DC PART NO. | AC/DC VOLTAGE | DATA SHEET |
|---|---|---|---|
2P | HSP1P 16 AC25 2P W-SCT HSP1P 16 DC25 2P W-SCT HSP1P 16 AC50 2P W-SCT HSP1P 16 DC50 2P W-SCT | 🟣 20~25V AC 🟣 20~25V DC ⚪ 36~50V AC ⚪ 36~50V DC | Download |
3P (2P + PE) | HSP1P 16 AC25 3P W-SCT HSP1P 16 DC25 3P W-SCT HSP1P 16 AC50 3P W-SCT HSP1P 16 DC50 3P W-SCT HSP1P 16 AC130 3P W-SCT HSP1P 16 AC250 3P W-SCT HSP1P 16 DC250 3P W-SCT | 🟣 20~25V AC 🟣 20~25V DC ⚪ 36~50V AC ⚪ 36~50V DC 🟡 110~130V AC 🔵 200~250V AC 🔵 50~250V DC | Download |
3P (1P + N + PE) | HSP1P 16 AC25 3P W-SCT HSP1P 16 AC50 3P W-SCT HSP1P 16 AC130 3P W-SCT | 🟣 20~25V AC ⚪ 36~50V AC 🟡 110~130V AC | Download |
4P (3P + PE) | HSP1P 16 AC250 4P W-SCT HSP1P 16 AC415 4P W-SCT HSP1P 16 AC500 4P W-SCT HSP1P 16 AC690 4P W-SCT | 🔵 200~250V AC 🔴 380~415V AC ◯ 480~500V AC ◯ 600~690V AC | Download |
5P (3P + N + PE) | HSP1P 16 AC250 5P W-SCT HSP1P 16 AC415 5P W-SCT HSP1P 16 AC500 5P W-SCT HSP1P 16 AC690 5P W-SCT | 🔵 200~250V AC 🔴 380~415V AC ◯ 480~500V AC ◯ 600~690V AC | Download |
AC/DC PART NO. | POLES | AC/DC VOLTAGE |
|---|---|---|
HSP1P 16 AC25 2P W-SCT / HSP1P 16 DC25 2P W-SCT HSP1P 16 AC50 2P W-SCT / HSP1P 16 DC50 2P W-SCT | 2P | 🟣 20~25V AC / 20~25V DC ⚪ 36~50V AC / 36~50V DC |
| PDFDownload | ||
HSP1P 16 AC25 3P W-SCT / HSP1P 16 DC25 3P W-SCT HSP1P 16 AC50 3P W-SCT / HSP1P 16 DC50 3P W-SCT HSP1P 16 AC130 3P W-SCT HSP1P 16 AC250 3P W-SCT / HSP1P 16 DC250 3P W-SCT | 3P (2P + PE) | 🟣 20~25V AC / 20~25V DC ⚪ 36~50V AC / 36~50V DC 🟡 110~130V AC 🔵 200~250V AC / 50~250V |
| PDFPobierz kartę katalogową | ||
HSP1P 16 AC25 3P W-SCT HSP1P 16 AC50 3P W-SCT HSP1P 16 AC130 3P W-SCT | 3P (1P + N + PE) | 🟣 20~25V AC ⚪ 36~50V AC 🟡 110~130V AC |
| PDFDownload | ||
HSP1P 16 AC250 4P W-SCT HSP1P 16 AC415 4P W-SCT HSP1P 16 AC500 4P W-SCT HSP1P 16 AC690 4P W-SCT | 4P (3P + PE) | 🔵 200~250V AC 🔴 380~415V AC ◯ 480~500V AC ◯ 600~690V AC |
| PDFDownload | ||
HSP1P 16 AC250 5P W-SCT HSP1P 16 AC415 5P W-SCT HSP1P 16 AC500 5P W-SCT HSP1P 16 AC690 5P W-SCT | 5P (3P + N + PE) | 🔵 200~250V AC 🔴 380~415V AC ◯ 480~500V AC ◯ 600~690V AC |
| PDFDownload | ||
Ambient temperature: -45°C to +65°C | Degree of protection: IP66 | Cable entry: M25 cable gland + M25 blanking plug Integrated switch: ON / OFF switching by rotating the plug in the socket |
||
PREISE ANZEIGEN / VERTRIEBSPARTNER WERDEN
Preisliste für Ex-Steckdosen und -Stecker
Safe connection and disconnection of the HSP1P plug
Step 0 – Pre-use check
To ensure an appropriate level of safety in a potentially explosive atmosphere, access to the socket may be restricted by a padlock. A built-in switch with a mechanical lock ensures that the plug can only be inserted or removed when the socket contacts are de-energised.
In the 16 A and 32 A versions, the switch is operated by turning the plug.
Step 1 – opening the protective cover
Unscrew the cover and tilt it upwards. The cover, together with the seal, protects the unused socket from dust and water, ensuring an IP66 rating. The kit is protected against incorrect connection and the use of an incompatible non-Ex plug. Mechanical coding ensures that only compatible components can be connected, whilst the distinctive colour makes it easy to identify their rated voltage. Once you have finished using the socket, tighten the cover securely.
Step 2 – fitting the plug
Align the plug according to the polarity markings and insert it as far as it will go. The spring-loaded design of the contact sleeves ensures constant pressure on the pins, minimises connection resistance and cleans their surfaces as they are inserted. This ensures a stable electrical connection even after repeated use of the set.
Step 3 – inserting the plug into the socket
Insert the plug straight into the socket, aligning it with the connection axis. Do not twist the plug as you insert it. The plug should be inserted fully, without using excessive force.
Step 4 – Sealing and securing the joint
Whilst holding the plug body firmly in place, tighten the locking ring as far as it will go. This ensures the connection is dust- and water-tight to IP66 standards and provides additional protection against the plug being accidentally pulled out.
Step 5 – switching on the circuit
Turn the plug body in the direction indicated until you hear a distinct click. This action activates the built-in switch, which only then supplies power to the socket contacts and mechanically locks the plug in place, preventing it from being removed whilst in use.
Step 6 – operating status
The plug should remain fully inserted, secured by the ring and in the operating position.
Do not attempt to unscrew the ring or remove the plug whilst the appliance is in use
Step 7 – switching off the circuit
When you have finished using the appliance, first switch off the power supply. Then turn the plug body from the ‘on’ position to the ‘off’ position.
The locking ring and the socket housing should remain stationary
Step 8 – Unblocking the connection
Whilst holding the plug body steady, turn the ribbed locking ring to the released position.
Do not unplug the power lead until the ring has been fully unlocked
Step 9 – removing the plug
Pull the plug straight out of the socket, keeping it aligned with the connection axis. Do not twist or tilt the plug whilst removing it
Step 10 – closing the protective cover
Once the plug has been completely removed, lower the protective cover and close the socket securely.
The cover protects the interior from dust and moisture when the socket is not in use.
Mobiles Ausstellungszentrum
Arbeitest du im „Ex“-Bereich an einem Projekt? Hast du das Gefühl, dass dein Wissen nicht ausreicht? Suchst du einen langfristigen Lieferanten oder denkst du darüber nach, deinen derzeitigen Lieferanten zu wechseln?
Jeder Grund ist gut genug, um einen Termin in unserem Handyshop zu vereinbaren.
Warum vereinbaren unsere Kunden einen Termin im Ausstellungszentrum für Handys?
Sie wollen in ihrem Werk die Qualität und Funktionalität der „HARDO“-Lösungen mit denen anderer Hersteller vergleichen
Das Team muss eine Schulung zur Montage und Auswahl von Ex-Geräten organisieren
In ihrem Unternehmen arbeitet man daran, die Ausrüstung zu standardisieren, und sucht nach der besten Lösung
Ich möchte den Kaufprozess beschleunigen, indem ich den Kunden die Möglichkeit gebe, das Gerät selbst anzuschauen und auszuprobieren
Ich möchte nicht nur die technischen Eigenschaften bewerten, sondern auch die Ergonomie und die Benutzerfreundlichkeit dieser Produkte
Er schätzt den direkten Kontakt und die Möglichkeit, mit den Ingenieuren zu sprechen, sehr
Überzeug dich selbst!
Schau dir an, wie unsere Produkte in echt aussehen, und wähle die aus, die du brauchst
Welche Branchen unterstützen wir?
Wir sind hier, um die besten Lösungen für die Industrie anzubieten. Finde heraus, wie wir deinem Unternehmen helfen können!





















