PrimeLine – first choice for Zone 1
3 variants: general lighting, emergency lighting with battery and for central battery
Electrical stability and high Power Factor of Ex ATEX luminaires
Compatible with a wide range of voltages
Efficient LED power supplies
Disconnection of the power supply when the diffuser is opened
Zone 1 luminaire operation in sub-zero temperatures
Durability, robustness and ease of installation
More than 100 possible configurations
Technical data
Photometric data: please see details below
Certifications: ATEX, IECEx, CNBOP
ATEX designation:
Ex II 2G Ex eb mb IIC T4 Gb (Certificate No: )
Ex II 2G Ex db eb mb IIC T4 Gb (for version with insulating switch disconnector)
Ex II 2D Ex tb IIIC T70°C Db (Certificate No: )
IECEx:
Ex tb IIIC T70°C Db ( Cert. nr: IECEx KSCP 23.0045X )
Ex eb mb IIC T4 Gb ( Cert. nr: IECEx KSCP 23.0045X )
Body material: GRP
Diffuser material: UV-stabilised polycarbonate
Diffuser in three versions: transparent / opal / frosted
Impact resistance: HIGH according to EN IEC 60079-0
IP: IP66/IP67
Colour temperature: 4000 K or 4500 K (optional: 5700K or 6500K)
CRI: >80 (optional: >70 or >90)
Ambient temperature: -40°C to +50°C (basic version) In emergency version with battery optional down to -20°C.
Price
PrimeLine’s Ex ATEX luminaires provide very good value for money and, thanks to the solutions used, can also significantly reduce the final costs of a lighting installation. Send a no-obligation enquiry to convince yourself of the cost-effectiveness of our luminaires.
High performance

Rapid opening

No loose parts

Two lengths

A new, competitive standard in zone 1 (gas) lighting:
The new Ex ATEX luminaire of the PrimeLine series for use in the first hazardous area is based on the proven OptiLine lamp design. Thanks to the use of already existing, reliable solutions, it will be possible to significantly reduce production costs, which will translate into a lower final price – by up to several to 30% compared to competitive solutions. One solution taken from the OptiLine luminaire is through wiring.

- makes it easy to combine luminaires
- eliminates expensive junction boxes
- reduces cable wear
- reduces assembly time
- provides flexibility in electrical connection
- reduces installation costs
Voltage disconnection when the diffuser is removed
PrimeLine explosion-proof luminaires can optionally be fitted with an integrated isolation switch, which automatically disconnects the power supply when the diffuser is open. This feature significantly improves safety and also simplifies both maintenance and testing procedures, especially in demanding industrial environments.

Enhanced user safety
Protection of internal components
Facilitated functional tests
High mechanical durability of the switch (up to 300,000 operations)
Wide operating temperature range of the switch (from -40°C to +100°C)
ATEX and IECEx compliance
Hinged diffuser and gear tray:
Great convenience when installing luminaires
Easy access to gable glands (from 1 to 4 M20 or M25 glands)
Quick opening
Easy access to precisely fitted components
All luminaire components are protected against falling out

PrimeLine – Ex ATEX LED luminaire for zone 1

Three lighting variants – versatile use
✔ Basic lighting,
✔ Emergency lighting with built-in battery,
✔ Emergency lighting under central addressable battery – built-in CBX module (optional CBY) ensures compatibility with Eaton systems.
Ex ATEX PrimeLine luminaires for use in Zone 1 explosive atmospheres come in two lengths – 670 mm and 1270 mm – to suit different applications and installation spaces.
Electrical stability and high Power Factor
Most Ex PrimeLine luminaire variants achieve a Power Factor ≥ 0.98, meaning minimal energy loss and electrical system stability, resulting in greater efficiency and lower operating costs. Variants for 230-250 VAC achieve PF = 0.98-0.99, confirming high quality and reliable performance under demanding conditions.
This high power factor reduces the load on the grid and improves the energy efficiency of the installation, which is particularly important in industrial applications. As a result, ATEX PrimeLine luminaires meet stringent quality standards and help optimise energy consumption in companies.
High-performance LED power supply in an Ex ATEX luminaire for zone 1
The PrimeLine luminaire uses state-of-the-art LED power supplies that provide:
✔ Optimisation of energy consumption,
✔ Excellent voltage stability for LED modules,
✔ High reliability in long-term operation.
Particularly noteworthy is the excellent voltage stability for the modules, which eliminates the risk of flickering and brightness dips. As a result, our ATEX luminaires for zone 1 ensure precise lighting conditions in technological processes requiring constant and uniform light intensity.
Compatible with a wide range of voltages
Ex PrimeLine luminaires can operate under various voltage conditions:
✔ 110 VAC, 50 Hz
✔ 220 VAC, 50 Hz
✔ 230 VAC, 50 Hz
✔ 240 VAC, 50 Hz
✔ 250 VAC, 50 Hz
Electrical and photometric data


PrimeLine length 670 mm, power 23.4 W
PrimeLine length 670 mm, power 28 W
PrimeLine length 670 mm, power 32.4 W
PrimeLine with a length of 1276 mm, power of 43 W
PrimeLine with a length of 1276 mm, power of 52.5 W
PrimeLine with a length of 1276 mm, power of 62 W
Parameters calculated for a temperature of 25oC, colour temperature 4000K, CRI > 80. Tolerance +/- 5%.
Klosz MROŻONY
Mocne, delikatnie rozproszone światło, bez efektu olśnienia
9 981 lm bez olśnienia
Inteligentny klosz minimalizuje ryzyko olśnienia i zmęczenia oczu.
Optymalny do użytku wewnątrz i na zewnątrz
Najlepsza równowaga pomiędzy intensywnością światła, a brakiem olśnienia.

Klosz MLECZNY
Rozwiązanie dedykowane do dużych pomieszczeń, w których często obecni są ludzie.
Najlepszy do użytku w pomieszczeniach
Brak olśnienia, brak zmęczenia oczu, bardzo dobre oddawanie barw
Idealny dla większych powierzchni
Specjalny klosz mocno rozprasza światło, nadając mu miękkość

Klosz TRANSPARENTNY
Mocne oświetlenie. Najlepsza wydajność. Najwyższa elastyczność.
Wysoka moc
Aż 10342 lm doskonale sprawdza się na zewnątrz oraz w wysokich pomieszczeniach.
Skieruj światło za pomocą 22 soczewek
Wyjątkowa możliwość swobodnej zmiany kierunku świecenia.

Dimensions and installation of Ex PrimeLine luminaire
Fixture type. | L | L1 | B |
---|---|---|---|
PrimeLine 60-********** | 670 | 400 | 173 |
PrimeLine 12-********** | 1276 | 800 | 173 |
Dimensions depend on mounting type. | H | B1 |
---|---|---|
Ceiling bracket D18. | 119 | 157 |
Ceiling bracket D40. | 143,7 | 200 |
M8 eye bolt for suspended mounting. | 154,2 | — |
Pole mount bracket R50. | 156,2 | — |
Wall bracket K45 | 184,7 | — |
Ceiling bracket C | 153,4 | — |
Dimensions in mm
Handle D18

D40 handle

R20 handle

R50 handle

Handle K45

Handle C

Photometry.
Download.
Instructions
With its clever design, wide configuration options and attractive price, the new EX ATEX luminaire for zone 1 will become a competitive alternative to current solutions on the market. Its high durability, mounting flexibility and compatibility with central power systems from EATON will make it the ideal solution for demanding industrial applications.
Luminous flux and colour of Ex ATEX luminaire for zone 1
PrimeLine will be characterised by its very high lumen output. Thus, in the category of ATEX luminaires for zone 1, few manufacturers will be able to offer better performance than PrimeLine.
For example:
- Short version luminaires; 4400lm at 125 lm/W
- Long version luminaires: over 8500lm at 145 lm/W
- Long version luminaires: over 8500lm at 145 lm/W
- Emergency versions working with a central battery: 50% of base flow
Three hours on battery
The Ex PrimeLine emergency luminaire with integrated battery is designed to operate for 1.5 hours or 3 hours, depending on the option chosen.
For applications in sub-zero temperatures, the option of fitting a heater is available, allowing the luminaire to operate stably and maintain battery performance. Thus, the version with heater also allows 1.5-hour emergency operation, even in severe weather conditions.
Certification and Safety
The new emergency luminaires will be ATEX- and IECEx-certified, and the versions for the Polish market will also be CNBOP-certified, ensuring compliance with the safety requirements applicable on the Polish and European markets.
Extremely negative operating temperatures of the emergency version with battery
One of the key advantages of the new Ex luminaire for Zone 1 hazardous area is that it can be used as an emergency version with a battery in sub-zero temperatures (down to -20°C), which is rare for this type of product. This solution makes it ideal for outdoor use, as well as in areas requiring cooling.
The ATEX PrimeLine luminaire is designed to operate in extreme temperatures, both negative and positive:
- Standard versions – from -40°C to +50°C (optional up to +55°C)
- Emergency versions – from 0°C to +45°C, (optional from -20°C)
- Versions with central battery – -30°C to +50°C