ATEX emergency lighting zone 22 and 21 and 2 for central battery

ATEX Emergency Light Fitting | Lighting for Zone 21, 22 and 2 [central battery]

ATEX Emergency Light Fitting | Lighting for zone 21, 22 and 2 [central battery]
ATEX LED emergency lighting fixture for central battery

Product features

Excellent quality-to-price ratio

Pass-through wiring eliminating junction boxes

Even 4 cable glands M20 or M25 for ease of installation

Lenses directing the light beam (optional)

Can be used as general lighting (optional)

3 diffusers providing varied light beams

Diffuser and internal mounting plate on hinges (no loose parts)

Atex Ex safety requirements for workplaces and equipment used in explosive atmospheres symbol

IECEx Ex symbol

CNBOP Ex logo

CE European health, safety, and environmental protection standards

IP66 ingress protection code symbol

Working temperature for -30 Celsius symbol

Working temperature for +40 Celsius symbol

Digital Addressable Lighting Interface protocol for digital lighting control symbol

Technical Data

Photometric data: please see details below

Certification: ATEX, IECEx, CNBOP

ATEX marking:

Atex Ex symbolII 2 D  Ex tb IIIC T70 °C Db ( Cert. no.: KSCP 23ATEX0021X )

Atex Ex symbolII 3 G  Ex ec mc IIC T4 Gc ( Cert. no.: KSCP 23ATEX0022X )

IECEx marking:

Ex tb IIIC T70 °C Db ( Cert. no.: IECEx KSCP 23.0045X )

Ex ec mc IIC T4 Gc ( Cert. no.: IECEx KSCP 23.0045X )

Material of Enclosure: GRP

Material of Diffuser: UV stabilized PC (Polycarbonate)

Diffuser in three versions: clear/ opal / frosted

Impact resistance: HIGH (acc. to EN IEC 60079-0)

IP rating: IP66 / IP67

Color Temperature: 4000 K (optionally: 3000K or 5000 K)

CRI: >80 (optionally: >70 or >90)

Ambient temperature: -30°C – +50°C (ATEX)

Price

Send us your request to receive a quotation.


Specify the number and size of glands and accessories (switches, lights, etc.). The system will suggest the minimum dimensions of the box. You will also be able to download a quote for the entire set.

Fast and cost efficient installation of lighting fixtures:

The ATEX OptiLine fixture features through-wiring with two easily accessible power connectors located at both ends of the lamp. The body of the lamp accommodates up to 4 cable glands M20 or M25. These solutions allow for the elimination of expensive Ex-rated junction boxes, as well as a reduction in the consumption of power cables and cable trays. Meanwhile, the larger M25 gland provides the flexibility to use cables from various manufacturers, including thicker non-flammable cables, as well as cables with increased conductor diameter to reduce voltage drops over distance.

  • connect luminaires in a pass-through manner
  • eliminate junction boxes
  • reduce power cable consumption
  • minimize cable trays and hanger usage
  • shorten luminaire installation time
  • lower lighting installation costs

Direct the light as you need

up to 22 additional lenses

easily illuminate key areas

avoid obstacles

one fixture, multiple light directions

easy lens replacement

OPTILINE 12-3 30 10 25 FROZEN (luminous intensity in a polar coordinate system)

Install quickly and safely – no loose parts:

the large space inside facilitates power connection

unscrew the screws by hand to quickly access the electronics

the open diffuser does not fall thanks to the hinges

the open plate with the LED module does not fall thanks to the hinges

all components of the fixture are interconnected

OPTILINE 12-3 30 10 25 FROZEN (luminous intensity in a polar coordinate system)

Description

box foto front

Construction

ATEX emergency fixtures from OptiLine series, designed to work with a central battery, are equipped with efficient LED light sources. The extended version of the fixture can be used as general lighting. Its external housing is made of glass-reinforced polyester (GRP). The diffuser, available in three variants (transparent, frosted, and opal), is made of UV-stabilized polycarbonate.

The ATEX OptiLine emergency fixture allows for the use of lens to adjust the direction of the light beam. With up to four cable glands (M20 or M25) and pass-through cables with electrical connectors on both ends of the fixture, installation and integration into larger systems are significantly simplified. These solutions eliminate the need for junction boxes, reduce cable consumption, cable trays, and other installation materials. The larger cable glands allow for the use of thicker cables from various manufacturers, including flame retardant and fire resistant cables and those with larger conductor cross-sections to minimize voltage drop over length.

The ATEX OptiLine emergency fixture has no loose parts. For example, the lens and the internal mounting plate have hinges, and the screws providing access to electrical connections are of the captive type. All of this eliminates the risk of elements of the fixture falling during installation and inspections.

Application

The OptiLine ATEX fixtures are designed for use both indoors and outdoors. They are intended for use in Zone 2, where there is a risk of explosion of gases, vapors, or mists of flammable liquids, assigned to explosion groups IIA, IIB, or IIC and temperature classes T4, T3, T2, T1. Additionally, they are suitable for use in Zones 21 and 22, where there is a risk of explosion of flammable dust of explosion groups IIIA, IIIB, or IIIC with a dust layer ignition temperature (5 mm thickness) higher than 145°C.

The OptiLine explosion-proof fixture has been designed for use in challenging and moderately demanding environments. Its high resistance to chemicals, mechanical damage, and environmental conditions make it suitable for industries such as chemical, petrochemical, energy, wood, and food processing.

Moreover, this fixture will prove valuable in all manufacturing plants and warehouses where high durability, safety confirmed by ATEX, IECEx, and CNBOP certifications, and well-thought-out construction that can reduce installation and maintenance costs are required.

Electrical and photometric data

OptiLine 670 mm length og 20 W power

Fixture type Diffuser
Type
FLuminous
flux [lm]
Efficacy
lm / W
Flux emergency
power [lm]
Voltage [V] Photometry
OptiLine 60-1****** CBX/CBY Clear: 3485 163 1650 AC 230, 50Hz / DC 230, 0Hz General
Emergency
Frosted: 3324 155 1560 AC 230, 50Hz / DC 230, 0Hz General
Emergency
Opal: 2931 137 1400 AC 230, 50Hz / DC 230, 0Hz General
Emergency

OptiLine 670 mm length og 25 W power

Fixture type Diffuser
Type
FLuminous
flux [lm]
Efficacy
lm / W
Flux emergency
power [lm]
Voltage [V] Photometry
OptiLine 60-2****** CBX/CBY Clear: 4422 169 2150 AC 230, 50Hz / DC 230, 0Hz General
Emergency
Frosted: 4218 162 2040 AC 230, 50Hz / DC 230, 0Hz General
Emergency
Opal: 3719 142 1820 AC 230, 50Hz / DC 230, 0Hz General
Emergency

OptiLine 670 mm length og 30 W power

Fixture type Diffuser
Type
FLuminous
flux [lm]
Efficacy
lm / W
Flux emergency
power [lm]
Voltage [V] Photometry
OptiLine 60-3****** CBX/CBY Clear: 5182 168 2550 AC 230, 50Hz / DC 230, 0Hz General
Emergency
Frosted: 4943 160 2420 AC 230, 50Hz / DC 230, 0Hz General
Emergency
Opal: 4358 141 2160 AC 230, 50Hz / DC 230, 0Hz General
Emergency

OptiLine 1276 mm length og 38 W power

Fixture type Diffuser
Type
FLuminous
flux [lm]
Efficacy
lm / W
Flux emergency
power [lm]
Voltage [V] Photometry
OptiLine 12-1****** CBX/CBY Clear: 6739 171 3270 AC 230, 50Hz / DC 230, 0Hz General
Emergency
Frosted: 6504 165 3100 AC 230, 50Hz / DC 230, 0Hz General
Emergency
Opal: 5700 144 2770 AC 230, 50Hz / DC 230, 0Hz General
Emergency

OptiLine 1276 mm length og 48 W power

Fixture type Diffuser
Type
FLuminous
flux [lm]
Efficacy
lm / W
Flux emergency
power [lm]
Voltage [V] Photometry
OptiLine 12-2****** CBX/CBY Clear: 8665 175 4100 AC 230, 50Hz / DC 230, 0Hz General
Emergency
Frosted: 8363 169 3890 AC 230, 50Hz / DC 230, 0Hz General
Emergency
Opal: 7329 148 3480 AC 230, 50Hz / DC 230, 0Hz General
Emergency

OptiLine 1276 mm length og 58 W power

Fixture type Diffuser
Type
FLuminous
flux [lm]
Efficacy
lm / W
Flux emergency
power [lm]
Voltage [V] Photometry
OptiLine 12-3***** CBX/CBY Clear: 10342 175 4900 AC 230, 50Hz / DC 230, 0Hz General
Emergency
Frosted: 9981 169 4650 AC 230, 50Hz / DC 230, 0Hz General
Emergency
Opal: 8747 148 4160 AC 230, 50Hz / DC 230, 0Hz General
Emergency

Parametere beregnet for temperatur 25oC, fargetemperatur 4000K, CRI > 80. Toleranse +/- 5 %.

FROSTED diffuser

Strong, softly diffused light without glare

9 981 lm without glare

Smart diffuser eliminates the risk of glare and eye fatigue.

Optimal for indoor and outdor

The best balance between light intensity and lack of glare.

OPTILINE 12-3 30 10 25 FROZEN (luminous intensity in a polar coordinate system)
OPTILINE 12-3 30 10 25 FROZEN (luminous intensity in a polar coordinate system)

OPAL diffuser

A solution dedicated to large spaces, where people are often present.

Best for indoor use

Zero glare, zero eye fatigue, very good color rendering

Lighting for larger areas

The special diffuser strongly diffuses the light, making it soft.

OPTILINE 12-3 30 10 25 OPAL (luminous intensity in a polar coordinate system) (1)
OPTILINE 12-3 30 10 25 OPAL (luminous intensity in a polar coordinate system) (1)

CLEAR diffuser

Powerful Illumination. Best efficiency. The highest flexibility.

Excellent power

Up to 10342 lm works perfectly outdoor.

Direct the light with 22 lenses

Exceptional ability to freely change the direction of illumination.

OPTILINE 12-3 30 10 25 CLEAR (luminous intensity in a polar coordinate system)

Dimensions and mounting options

Fixture typeLL1B
OptiLine 60-**********670400173
OptiLine 12-**********1276800173
Dimensions depend on mounting typeHB1
Ceiling bracket D18119157
Ceiling bracket D40143,7200
M8 eye bolt for suspended mounting154,2
Pole mount bracket R50156,2
Wall bracket K45184,7
Ceiling bracket C153,4

All dimensions are in millimeters (mm)

Ceiling bracket D18

Ceiling bracket D40

M8 eye bolt for uspended mounting

Pole mount bracket R50

Wall bracket K45

Ceiling bracket C

Photometry

Download

ATEX Emergency LED Fixtures: Cost Savings and Enhanced Safety in Hazardous Areas

When it comes to lighting in hazardous areas, the costs of ATEX (ATmosphères EXplosibles) lighting fixtures are just one piece of the puzzle. The installation of these fixtures can constitute a significant portion of the total expenses, often ranging from 20% to 40%. In this article, we will examine how the appropriate selection of ATEX lamps and fixtures can not only reduce installation costs but also improve safety in explosive hazard Zones.

Choosing ATEX Lamps and Installation Costs

Before we introduced our Ex LED lighting fixtures to the market, we spent years designing complete general and emergency lighting installations, which we then installed in our clients’ facilities. Our practical experience with lighting fixtures from various manufacturers allowed us to understand the factors that influence the final costs of lighting installations, including emergency lighting, in Ex (explosive hazard) areas.

We discovered that the choice of lighting fixtures has a significant impact on installation efficiency, the speed of work execution, and the consumption of installation materials, including cable trays, power cables, and junction boxes.

Here are a few important points to remember:

  1. Lighting fixtures for Ex Zones require the use of more expensive, ATEX-certified junction boxes.
  2. Emergency fixtures require the use of more expensive, flame retardant and fire resistant power cables and junction boxes.
  3. Some industries require the use of stainless steel installation materials, which increases costs associated with junction boxes, cable trays, and other components.

Up to 4 Cable Glands in ATEX Fixtures

Many lighting fixtures have limitations when it comes to the number and size of cable glands that can be installed on their enclosures. ATEX OptiLine fixtures can accommodate up to four cable glands of M20 or M25 types (two on each side). This, combined with pass-through cables featuring two electrical connections at both ends of the fixture, allows for versatile fixture connections without the need for junction boxes and with reduced consumption of power cables and cable trays.

Larger Cable Gland Size

The use of M25 cable glands in ATEX emergency fixtures allows for the use of cables with a larger cross-sectional area. This not only provides flexibility in choosing cable manufacturers but also enables the use of thicker cables with increased conductor diameter to reduce voltage drops over longer distances. It also facilitates the use of flame retardant and fire resistant cables, which is crucial for emergency fixtures.

Efficient and Safe Installation

Our ATEX lighting fixtures have been designed with safety and convenience in mind. The diffuser and internal mounting plate with the LED module feature a type of hinge, making it easier to access electrical components without the risk of them falling. Importantly, if necessary, the diffuser can be completely detached from the housing. But that’s not all. The mounting screws are captive screws and have specially profiled heads for easy removal by hand or with a screwdriver.

Considering the above, OptiLine Ex fixtures ensure that no components will fall during installation, enhancing the safety of the work and eliminating the risk of foreign objects entering the production equipment, which could lead to contamination of the product or be the cause of mechanical sparking.

Choosing the Right ATEX Fixture for Lighting

As manufacturers of explosion-proof lighting fixtures with experience in installing lighting installations, we have identified several challenges that can increase investment costs. Drawing from this experience, we have developed the versatile OptiLine ATEX emergency lighting fixture designed to handle both general and emergency lighting in explosive hazard Zones while maintaining competitive fixture prices.

Let’s take a closer look at a few key features of the OptiLine fixture that contribute to reducing installation costs in industrial lighting installations.

Combining General and Emergency Lighting Functions

OptiLine LED lamps can function as both general and emergency lighting. This eliminates the need for separate installations, providing flexibility and efficiency. Emergency lighting can be powered either from a central battery (OptiLine CBX/CBY model) or the built-in battery within the fixture (OptiLine A1 model).

Wide Range of Light Outputs

ATEX OptiLine lighting fixtures come in two lengths and offer six levels of light output. Combined with three different options for diffuser transparency, this provides a wide range of light output possibilities, allowing them to be tailored to various lighting requirements.

Three Different Diffuser for Various Applications

ATEX OptiLine fixtures provide a choice of three diffuser: transparent, frosted, and opal. Each type of diffuser has unique light transmission properties, allowing for customization of the lighting to specific environments, whether it’s outdoors, indoors, or requiring a diffused light beam.

Adjusting the Lighting Direction with Lenses

The ATEX OptiLine fixture allows for the use of lenses to adjust the direction of lighting. This innovative solution simplifies installation and leads to cost savings by eliminating the need for special brackets or accessories.

Transforming ATEX Lighting Fixtures into High-Bay Solutions

By using a special focusing lens, OptiLine lighting fixtures are suitable for installation at significant heights. This eliminates the need for High-Bay fixtures or special constructions, resulting in cost savings and providing uniform lighting throughout the space.

Variable Light Output in Emergency Mode

Each ATEX OptiLine emergency lighting fixture can be configured to emit different levels of light output in emergency mode. This flexibility simplifies the design process and positively impacts installation costs. Instead of relying on costly control systems or adjusting mounting heights, you can individually set the light output for each fixture.


What are ATEX / IECEx OptiLine luminaires

ATEX / IECEx OptiLine luminaires refer to a specific type of lighting product that combines the features and certifications of both ATEX and IECEx standards. These luminaires are designed and manufactured to meet the safety requirements and regulations outlined by both ATEX and IECEx for use in potentially explosive atmospheres. They incorporate high-efficiency LED light sources and are suitable for both basic and emergency lighting applications. The designation of “ATEX / IECEx OptiLine luminaires” signifies that these luminaires have obtained certifications from both ATEX and IECEx, ensuring their compliance with the highest safety standards for hazardous environments.

Why to use an ATEX / IECEx OptiLine luminaires

ATEX / IECEx OptiLine luminaires should be used in environments with potentially explosive atmospheres because they are specifically designed and certified to ensure safety and compliance with stringent regulations. These luminaires provide energy-efficient lighting, durability against challenging conditions, and versatility for both basic and emergency lighting needs. By using them, organizations can prioritize the safety of their workers, meet regulatory requirements, and benefit from reliable and efficient lighting solutions in hazardous locations.