STAINLESS STEE Ex Control Stations Standar

STAINLESS STEEL Ex Control Stations Plus

STAINLESS STEE Ex Control Stations Standar

Product features

High corrosion resistance

Hinged cover as option

Internal mounting plate as option

Cable glands plate as an option

Atex Ex symbol

IECEx Ex symbol

IP68 Ex symbol

IP66 Ex symbol

Technical Data

Dimensions: please see details below

Certification: ATEX, IECEx

ATEX marking:

Atex Ex symbolII 2 G Ex db eb ia/ib mb IIC/IIB T6…T4 Gb

Atex Ex symbolII 2 D Ex tb IIIC T85°C… T135°C Db

IECEx marking:
Ex db eb ia/ib mb IIC/IIB T6…T4 Gb
Ex tb IIIC T85°C… T135°C

Material: Stainless Steel

Ambient temperature:
-50°C – +60°C (ATEX)
-50°C – +60°C (IECEx – up to +95°C for special “HT” models)

IP rating: IP66

Rated voltage: max 1000V

Rated current: max 160A

Price

Send us your request to receive a quotation.


Specify the number and size of glands and accessories (switches, lights, etc.). The system will suggest the minimum dimensions of the box. You will also be able to download a quote for the entire set.

Description

STAINLESS STEE Ex Control Stations Standar
STAINLESS STEE Ex Control Stations Standar

Construction

ATEX / IECEx enclosures of HCS1S series control stations are made of stainless steel AISI 316L. Stainless steel enclosures provide HARDO control stations with the highest resistance to corrosive agents. HCS1S series of control stations has following features:

body and cover are made of stainless steel AISI 316L.

stainless steel anti-loosening screws on cover.

polyuretane or silicone cover gasket.

stainless steel internal fixing screws.

enclosures are available in three different executions: cover fixed to body by antiloosening screws; cover jointed to body by hinges and locking keys; cover jointed to body by hinges and by anti-loosening screws. All systems provide the right pressure on gasket to grant the IP66 protection to the enclosure. When the cover is connected to the body by hinges, it may be possible to provide extra cable entries on each side wall by adding gland plates.

stainless steel internal mounting plates are available.

Function

Control Station HCS1S enclosures are often used for the following primary applications:

command and control stations

emergency call systems

instrument enclosures

breaker panels

toggle switches and changeover switches

lighting adjustments

terminal units

electrical enclosure

Battery holder

Control Station enclosures are available in a variety of sizes enabling you to choose an enclosure that is the best fit for your application. Control Station enclosures can be mounted together using specific flanges to form a big panel while retaining the IP protection of each individual enclosure. Starting at 90 mm in height, the enclosures can be outfitted with cover operators (pilot lights, push buttons, switches, etc.).

Dimensions

STAINLESS STEE Ex Control Stations Standar
STAINLESS STEE Ex Control Stations Standar
TYPEABCDE
HCS1S101210100120100150-
HCS1S142013140200130170-
HCS1S151510150150100180-
HCS1S202016200200160230160
HCS1S202713200270130230230
HCS1S202716200270160230230
HCS1S272713270270130300230
HCS1S273513270350130300310
HCS1S273516270350160300310
HCS1S282816280280160310240
HCS1S282827280280270310240
HCS1S353516350350160380310
HCS1S353520350350200380310
HCS1S355016350500160380460
HCS1S355020350500200380460
HCS1S383816380380160410340
HCS1S383820380380200410340
HCS1S383827380380270410340
HCS1S384516380450160410410
HCS1S384520380450200410410
HCS1S385716380570160410530
HCS1S505016500500160530460
HCS1S505020500500200530460
HCS1S575716570570160600530
HCS1S575720570570200600530
HCS1S575730570570300600530
HCS1S577620570760200600720
HCS1S769520760950200790910

Components

HCS1S series control stations can be fitted with a wide variety of certified components from leading global manufacturers. Among these components are pushbuttons, pilot and signal lamps, emergency mushroom head pushbuttons, circuit breakers, relays, isolator switches and measuring devices.

Push Buttons

Spring-return pushbutton units and spring-return double pushbuttons can be combined with various types of contact modules in order to provide many different combinations of NO and NC contacts. These units are available in different colours and, as an option, may be fitted with various marking labels.

Emergency Mushroom Head Pushbuttons

Spring return mushroom head pushbutton units, complete with one electrical contact module.

Push-pull emergency mushroom head pushbutton units (with or without key extraction), complete with one electrical contact module.

Turn-to-release emergency mushroom head pushbutton units complete with one electrical contact module.

Selector Switches

Stay-put or spring return key selector units complete with one electrical contact module.

Signal Lamps

Signal lamps approved for use in hazardous areas. They come complete with an LED unit designed for different voltages as per electrical circuit requirements.  Signal lamps are available in different colors.

Signal Lamps with Button

Spring-return illuminated push button unit. Complete with LED unit, available in different voltages and with one electrical contact. Available with different combinations of NO and NC contacts. Available in different colours.

Potentiometers

Potentiometer unit with range of resistance values. The knob is provided with a large visual display.

Voltmeters, Ammeters, Miliammeters

The HVA (Harmonic Voltage Analysis) Voltmeter, Ammeter, Miliammeter units are available with a large number of measuring range options, scaled 2 or 5 times. The ammeter unit can make a direct measurement or be used in conjunction with current transformers and upon request, secondary current transformers. The ammeter has a working temperature range from -40°C to +60°C

Switch module 2 – Pole

Two separate pressing rods controlling a group of contacts each. One group or two groups of contacts can be controlled by different operation heads to have different functions.

Switch module 4 – Pole

Two separate metal pressing elements, controlling two group of contacts each. Two groups or four groups of contacts can be controlled by different operation heads to have different functions.

Protective Window

Pilot light window of thermoresistant glass sealed with auto-leveling silicone. 

Circuit breakers

Circuit breakers are devices that shut off power flow when a short circuit occurs. They are designed to protect people in potentially explosive atmospheres and can be used with currents of 6, 10, 16, 20, 25, 32 or 40 amps, with residual currents of 10, 30, 100 and 300 milliamps.

Contactors Rated voltage 24 V / 240 V

Contactors are compact components for Ex e enclosures in Zones 1 and 2, and are durable and reliable for use in hazardous areas. All are easy to install, rugged and corrosion-resistant. The contactors are mounted in Ex e protected enclosures and can be used for a wide variety of applications.

Load Isolation Switches with Handle for currents up to 180 A

Load isolation switch module is certified and must be installed in an increased safety “Ex e” enclosure. It has good flame retardant performance and fast connect or breaking once the spring is tight to release. Wire terminals’ screws are made of stainless steel. 

Cable Glands

Cable Glands are devices that are used to connect and fasten the end of an electrical cable to the target equipment. Cable Glands are used for all types of power, control, instrumentation, data and communications cables. There are cable glands for non-armoured and armoured cables. In addition to a wide range of cable glands other accessories like adaptors, reducers and stopping plugs are available. 

ATEX control station made of stainless steel – advantages


Highly hygienic and easy to clean

Stainless steel control stations are also highly hygienic and easy to clean, making them suitable for use in the food and beverage industry. Stainless steel surfaces are smooth and non-porous which makes them resistant to bacteria and other pathogens. In addition, they can be easily cleaned and sanitized, which is crucial in industries where hygiene is critical.

High strength and robustness

Stainless steel control stations offer several advantages over other types of control stations, particularly in hazardous areas. One key advantage is their high strength and robustness. Stainless steel is a very strong material which means that control stations made from this material can withstand harsh environmental conditions and physical impacts better than other materials.

Long-lasting

Stainless steel control stations are highly durable and long-lasting. They can withstand impacts, vibrations and other types of mechanical stress which can help ensure reliable operation in harsh environments. In addition, stainless steel control stations are resistant to fire and explosions which is crucial in hazardous environments where these risks are present.

Summary

Overall, stainless steel control stations offer a durable, heat-resistant, corrosion-resistant, hygienic and visually appealing solution for controlling equipment in hazardous areas. Their high strength, temperature resistance and easy-to-clean surfaces make them ideal for a wide range of applications in industries such as chemical processing, oil and gas, marine, pharmaceutical, food and beverage and more.