ATEX emergency lighting zone 22 and 21 and 2 for central battery

PrimeLine LED Ex ATEX emergency luminaire for Zone 1 [central battery]

PrimeLine LED Ex ATEX explosion protection emergency luminaire for zone 1 [central battery]
ATEX LED luminaire for zone 1

PrimeLine – first choice for Zone 1

3 variants: general lighting, emergency lighting with battery and for central battery

Electrical stability and high Power Factor of Ex ATEX luminaires

Compatible with a wide range of voltages

Efficient LED power supplies

Disconnection of the power supply when the diffuser is opened

Zone 1 luminaire operation in sub-zero temperatures

Durability, robustness and ease of installation

More than 100 possible configurations

Atex Ex safety requirements for workplaces and equipment used in explosive atmospheres symbol

IECEx Ex symbol

CNBOP Ex logo

CE European health, safety, and environmental protection standards

IP66 ingress protection code symbol

Working temperature for -40 Celsius symbol

Working temperature 50 Celsius  icon

Digital Addressable Lighting Interface protocol for digital lighting control symbol

Technical data

Photometric data: please see details below

Certifications: ATEX, IECEx, CNBOP

ATEX designation:

Atex Ex symbolEx II 2G Ex eb mb IIC T4 Gb (Certificate No: )

Atex Ex symbolEx II 2G Ex db eb mb IIC T4 Gb (for version with insulating switch disconnector)

Atex Ex symbolEx II 2D Ex tb IIIC T70°C Db (Certificate No: )

IECEx:

Ex tb IIIC T70°C Db ( Cert. nr: IECEx KSCP 23.0045X )

Ex eb mb IIC T4 Gb ( Cert. nr: IECEx KSCP 23.0045X )

Body material: GRP

Diffuser material: UV-stabilised polycarbonate

Diffuser in three versions: transparent / opal / frosted

Impact resistance: HIGH according to EN IEC 60079-0

IP: IP66/IP67

Colour temperature: 4000 K or 4500 K (optional: 5700K or 6500K)

CRI: >80 (optional: >70 or >90)

Ambient temperature: -40°C to +50°C.

Price

PrimeLine’s Ex ATEX explosion-proof emergency luminaires provide very good value for money and, thanks to the solutions used, can also significantly reduce the final cost of the lighting installation. Send a no-obligation enquiry to convince yourself of the cost-effectiveness of our luminaires.


Specify the number and size of glands and accessories (switches, lights, etc.). The system will suggest the minimum dimensions of the box. You will also be able to download a quote for the entire set.

EX ATEX emergency lights for zone 1 powered from a central battery

PrimeLine emergency luminaires are equipped with an integrated CB module that reduce production costs allowing for direct integration with modern central power supply and monitoring systems. This enables each luminaire to be individually monitored and controlled from a central unit, without the need for additional devices. PrimeLine luminaires are fully compatible with CEAG central battery systems, making them easy to integrate into advanced emergency lighting monitoring and management systems.

  • Automatic execution of function and duration tests
  • High level of safety
  • Simplified installation
  • Shared mains and emergency power connection
  • Up to 20 luminaires in single circuit
  • Fully compatible with CEAG central battery systems

Up to 4 cable glands and through-wiring

The use of tried-and-tested technologies and off-the-shelf components has made it possible to significantly reduce production costs, allowing the luminaire to be offered at an extremely attractive price – up to 30% lower than comparable solutions available on the market. One significant improvement, adapted from the renowned OptiLine luminaire, is the pass-through wiring system, which significantly simplifies installation and increases mounting flexibility.

  • Allows luminaires to be easily combined
  • Eliminates expensive junction boxes
  • Reduces cable wear
  • Reduces assembly time
  • Provides flexibility in electrical connection
  • Reduces installation costs

Integrated isolator switch – safety and simplified maintenance

In demanding industrial environments, an especially useful option for PrimeLine explosion-proof luminaires is the integrated isolating switch. Automatic power disconnection when opening the cover significantly improves handling and increases safety levels.

Enhanced user safety

Protection of internal components

Facilitated functional tests

High mechanical durability of the switch (up to 300,000 operations)

Wide operating temperature range of the switch (from -40°C to +100°C)

ATEX and IECEx compliance

Hinged diffuser and gear tray:

Great convenience when installing luminaires

Easy access to gable glands (from 1 to 4 M20 or M25 glands)

Quick opening

Easy access to precisely fitted components

All luminaire components are protected against falling out

PrimeLine for central battery: explosion-proof emergency lamp for zone 1

box photo front

Three lighting options for tough working conditions

Ex PrimeLine lamps offer three independent operating variants, enabling them to be used in a wide variety of projects:

✔ Basic lighting – safe lighting for industry every day,
Emergency with own power supply – integrated battery guarantees emergency operation for 1.5 or 3 hours,
Centrally powered emergency with addressable function – the CBX module (optional CBY) allows full integration into the Eaton infrastructure, providing advanced lighting management.

High power factor – real energy savings

Thanks to the use of advanced electronics, most Ex PrimeLine models achieve a Power Factor above 0.98. This means, among other things:

Improved power quality,
Stability of the overall electrical installation,
Lower operating costs.

Variants powered at 230-250 VAC achieve PF = 0.98-0.99, confirming the highest quality and reliability in the most demanding industrial environments. Such a high Power Factor reduces the load on the network and promotes the energy efficiency of the installation – which translates directly into savings.

LED power supplies for reliable operation in 1 EX-zone

Each luminaire uses high-performance LED power supplies that offer:
Energy efficient operation,
Stable power supply for the LED modules,
Extended life of the lighting system.

Thanks to precise voltage regulation, flickering effects or drops in brightness are eliminated. This is crucial where uniform, continuous light is required – for example, in industrial and technological applications.

Power supply? Flexibility as standard

Ex PrimeLine emergency lights are designed to operate in a variety of voltage conditions:
110 VAC, 50 Hz
220 VAC, 50 Hz
230 VAC, 50 Hz
240 VAC, 50 Hz
250 VAC, 50 Hz

Thanks to this versatility, PrimeLine luminaires will work well in many countries and a wide variety of installations – without the need for additional adaptation.

Length of lamp to suit the space

Two housing sizes – 670 mm and 1270 mm – are available, allowing the luminaire to be optimally matched to the installation conditions and the specifics of explosive atmospheres (especially zone 1).

Electrical and photometric data

PrimeLine with a length of 670 mm, power of 24.6 W

Luminaire model.Type
diffuser
Luminous flux
lm
Efficiency
lm / W
Luminous flux
lm power
Voltage [V]Photometry.
PrimeLine 60-1 ****XTransparent28391151420AC 230, 50Hz / DC 230, 0Hz
Frosted27251151362AC 230, 50Hz / DC 230, 0Hz
Opal24131151206AC 230, 50Hz / DC 230, 0Hz

PrimeLine with 670 mm length, 29.4 watts of power

Luminaire model.Type
diffuser
Luminous flux
lm
Efficiency
lm / W
Luminous flux
lm power
Voltage [V]Photometry.
PrimeLine 60-2 ****XTransparent35861221793AC 230, 50Hz / DC 230, 0Hz
Frosted34431221721AC 230, 50Hz / DC 230, 0Hz
Opal30481221524AC 230, 50Hz / DC 230, 0Hz

PrimeLine with 670 mm length, 33.5 W output

Luminaire model.Type
diffuser
Luminous flux
lm
Efficiency
lm / W
Luminous flux
lm power
Voltage [V]Photometry.
PrimeLine 60-3 ****XTransparent41791252089AC 230, 50Hz / DC 230, 0Hz
Frosted:40121252006AC 230, 50Hz / DC 230, 0Hz
Frosted:35521251776AC 230, 50Hz / DC 230, 0Hz

PrimeLine with a length of 1276 mm, power of 44.2 W

Luminaire model.Type
diffuser
Luminous flux
lm
Efficiency
lm / W
Luminous flux
lm power
Voltage [V]Photometry.
PrimeLine 12-1 ****XTransparent58001312900AC 230, 50Hz / DC 230, 0Hz
Frosted55681312784AC 230, 50Hz / DC 230, 0Hz
Opal49301312465AC 230, 50Hz / DC 230, 0Hz

PrimeLine with a length of 1276 mm, power of 54 W

Luminaire model.Type
diffuser
Luminous flux
lm
Efficiency
lm / W
Luminous flux
lm power
Voltage [V]Photometry.
PrimeLine 12-2 ****XTransparent71001313550AC 230, 50Hz / DC 230, 0Hz
Frosted68161313408AC 230, 50Hz / DC 230, 0Hz
Opal60351313017AC 230, 50Hz / DC 230, 0Hz

PrimeLine with a length of 1276 mm, power 63.5 W

Luminaire model.Type
diffuser
Luminous flux
lm
Efficiency
lm / W
Luminous flux
lm power
Voltage [V]Photometry.
PrimeLine 12-3 ****XTransparent83001314150AC 230, 50Hz / DC 230, 0Hz
Frosted79681313984AC 230, 50Hz / DC 230, 0Hz
Opal70551313527AC 230, 50Hz / DC 230, 0Hz

Parameters calculated for a temperature of 25oC, colour temperature 4000K, CRI > 80. Tolerance +/- 5%.

Klosz MROŻONY

Mocne, delikatnie rozproszone światło, bez efektu olśnienia

9 981 lm bez olśnienia

Inteligentny klosz minimalizuje ryzyko olśnienia i zmęczenia oczu.

Optymalny do użytku wewnątrz i na zewnątrz

Najlepsza równowaga pomiędzy intensywnością światła, a brakiem olśnienia.

OPTILINE 12-3 30 10 25 mrozony (luminous intensity in a polar coordinate system)pl.webp
OPTILINE 12-3 30 10 25 mrozony (luminous intensity in a polar coordinate system)pl.webp

Klosz MLECZNY

Rozwiązanie dedykowane do dużych pomieszczeń, w których często obecni są ludzie.

Najlepszy do użytku w pomieszczeniach

Brak olśnienia, brak zmęczenia oczu, bardzo dobre oddawanie barw

Idealny dla większych powierzchni

Specjalny klosz mocno rozprasza światło, nadając mu miękkość

OPTILINE 12-3 30 10 25 mleczny (luminous intensity in a polar coordinate system)pl.webp
OPTILINE 12-3 30 10 25 mleczny (luminous intensity in a polar coordinate system)pl.webp

Klosz TRANSPARENTNY

Mocne oświetlenie. Najlepsza wydajność. Najwyższa elastyczność.

Wysoka moc

Aż 10342 lm doskonale sprawdza się na zewnątrz oraz w wysokich pomieszczeniach.

Skieruj światło za pomocą 22 soczewek

Wyjątkowa możliwość swobodnej zmiany kierunku świecenia.

OPTILINE 12-3 30 10 25 transparentny (natężenie światła w układzie współrzędnych biegunowych)pl.webp
OPTILINE 12-3 30 10 25 transparentny (natężenie światła w układzie współrzędnych biegunowych)pl.webp

Dimensions and installation of Ex PrimeLine luminaire

Fixture type.LL1B
PrimeLine 60-**********670400173
PrimeLine 12-**********1276800173
Dimensions depend on mounting type.HB1
Ceiling bracket D18.119157
Ceiling bracket D40.143,7200
M8 eye bolt for suspended mounting.154,2
Pole mount bracket R50.156,2
Wall bracket K45184,7
Ceiling bracket C153,4

Dimensions in mm

Handle D18

D40 handle

R20 handle

R50 handle

Handle K45

Handle C

Photometry.

Download.

PrimeLine – Ex ATEX industrial emergency lamp for zone 1 ready for any conditions

The new PrimeLine range of explosion-proof emergency lights under the central Ex ATEX battery has been designed as an efficient, reliable and versatile answer to the needs of industry. With a proven design, a wide range of options and an attractive price, PrimeLine will work well in both new installations and retrofitting of existing systems. Interoperability with Eaton central battery systems ensures seamless integration with central emergency power supply.

Optional emergency power supply from integrated battery – reliable for up to 3 hours

If, instead of being powered by a central battery, you decide to choose the option of an emergency explosion-proof lamp for zone 1 powered by an internal battery, the luminaire can operate in emergency mode for 1.5 or 3 hours, depending on the configuration. Versions suitable for sub-zero temperatures can be equipped with an integrated heater to stabilise battery conditions and ensure uninterrupted lighting in all conditions.

Lighting parameters that make a difference

The ATEX PrimeLine emergency lights feature above-average light output – one of the product’s strongest points:

  1. Shorter version: 4400 lumens at 125 lm/W
  2. Longer version: more than 8500 lumens at 145 lm/W
  3. Emergency variants with CB: 50% of basic light intensity

Suitable for harsh conditions – low and high temperatures

PrimeLine has been developed with extreme temperatures in mind. The emergency version with battery can operate even at -20°C and the standard models from -40°C to +50°C (with option up to +55°C). The versions with a central battery can withstand temperatures from -30°C to +50°C.

Certification at international level

Our PrimeLine emergency lamp powered by a central battery has full ATEX and IECEx certification, ensuring compliance with safety standards for explosive atmospheres worldwide. A CNBOP-approved version will also be available for the Polish market, which guarantees compliance with local regulations and formal requirements for emergency lighting.