![PrimeLine LED Ex ATEX explosion protection emergency luminaire for zone 1 [central battery]](https://hardo.tech/wp-content/uploads/2025/04/PrimeLine-typy-kloszy-wymiary-centralna-bateria-EN.jpg)
PrimeLine – first choice for Zone 1
3 variants: general lighting, emergency lighting with battery and for central battery
Electrical stability and high Power Factor of Ex ATEX luminaires
Compatible with a wide range of voltages
Efficient LED power supplies
Disconnection of the power supply when the diffuser is opened
Zone 1 luminaire operation in sub-zero temperatures
Durability, robustness and ease of installation
More than 100 possible configurations



 
 
 
 
 
 
 
 
Technical data
Photometric data: please see details below
Certifications: ATEX, IECEx, CNBOP
ATEX designation:
Ex II 2G Ex eb mb IIC T4 Gb (Certificate No: )
Ex II 2G Ex db eb mb IIC T4 Gb (for version with insulating switch disconnector)
Ex II 2D Ex tb IIIC T70°C Db (Certificate No: )
IECEx:
Ex tb IIIC T70°C Db ( Cert. nr: IECEx KSCP 23.0045X )
Ex eb mb IIC T4 Gb ( Cert. nr: IECEx KSCP 23.0045X )
Body material: GRP
Diffuser material: UV-stabilised polycarbonate
Diffuser in three versions: transparent / opal / frosted
Impact resistance: HIGH according to EN IEC 60079-0
IP: IP66/IP67
Colour temperature: 4000 K or 4500 K (optional: 5700K or 6500K)
CRI: >80 (optional: >70 or >90)
Ambient temperature: -40°C to +50°C.
Price
PrimeLine’s Ex ATEX explosion-proof emergency luminaires provide very good value for money and, thanks to the solutions used, can also significantly reduce the final cost of the lighting installation. Send a no-obligation enquiry to convince yourself of the cost-effectiveness of our luminaires.
High performance

Rapid opening

No loose parts

Two lengths

EX ATEX emergency lights for zone 1 powered from a central battery
PrimeLine emergency luminaires are equipped with an integrated CB module that reduce production costs allowing for direct integration with modern central power supply and monitoring systems. This enables each luminaire to be individually monitored and controlled from a central unit, without the need for additional devices. PrimeLine luminaires are fully compatible with CEAG central battery systems, making them easy to integrate into advanced emergency lighting monitoring and management systems.

- Automatic execution of function and duration tests
- High level of safety
- Simplified installation
- Shared mains and emergency power connection
- Up to 20 luminaires in single circuit
- Fully compatible with CEAG central battery systems
Up to 4 cable glands and through-wiring
The use of tried-and-tested technologies and off-the-shelf components has made it possible to significantly reduce production costs, allowing the luminaire to be offered at an extremely attractive price – up to 30% lower than comparable solutions available on the market. One significant improvement, adapted from the renowned OptiLine luminaire, is the pass-through wiring system, which significantly simplifies installation and increases mounting flexibility.

- Allows luminaires to be easily combined
- Eliminates expensive junction boxes
- Reduces cable wear
- Reduces assembly time
- Provides flexibility in electrical connection
- Reduces installation costs
Integrated isolator switch – safety and simplified maintenance
In demanding industrial environments, an especially useful option for PrimeLine explosion-proof luminaires is the integrated isolating switch. Automatic power disconnection when opening the cover significantly improves handling and increases safety levels.

Enhanced user safety
Protection of internal components
Facilitated functional tests
High mechanical durability of the switch (up to 300,000 operations)
Wide operating temperature range of the switch (from -40°C to +100°C)
ATEX and IECEx compliance
Hinged diffuser and gear tray:
Great convenience when installing luminaires
Easy access to gable glands (from 1 to 4 M20 or M25 glands)
Quick opening
Easy access to precisely fitted components
All luminaire components are protected against falling out

PrimeLine for central battery: explosion-proof emergency lamp for zone 1

Three lighting options for tough working conditions
Ex PrimeLine lamps offer three independent operating variants, enabling them to be used in a wide variety of projects:
✔ Basic lighting – safe lighting for industry every day,
✔ Emergency with own power supply – integrated battery guarantees emergency operation for 1.5 or 3 hours,
✔ Centrally powered emergency with addressable function – the CBX module (optional CBY) allows full integration into the Eaton infrastructure, providing advanced lighting management.
High power factor – real energy savings
Thanks to the use of advanced electronics, most Ex PrimeLine models achieve a Power Factor above 0.98. This means, among other things:
✔ Improved power quality,
✔ Stability of the overall electrical installation,
✔ Lower operating costs.
Variants powered at 230-250 VAC achieve PF = 0.98-0.99, confirming the highest quality and reliability in the most demanding industrial environments. Such a high Power Factor reduces the load on the network and promotes the energy efficiency of the installation – which translates directly into savings.
LED power supplies for reliable operation in 1 EX-zone
Each luminaire uses high-performance LED power supplies that offer:
✔ Energy efficient operation,
✔ Stable power supply for the LED modules,
✔ Extended life of the lighting system.
Thanks to precise voltage regulation, flickering effects or drops in brightness are eliminated. This is crucial where uniform, continuous light is required – for example, in industrial and technological applications.
Power supply? Flexibility as standard
Ex PrimeLine emergency lights are designed to operate in a variety of voltage conditions:
✔ 110 VAC, 50 Hz
✔ 220 VAC, 50 Hz
✔ 230 VAC, 50 Hz
✔ 240 VAC, 50 Hz
✔ 250 VAC, 50 Hz
Thanks to this versatility, PrimeLine luminaires will work well in many countries and a wide variety of installations – without the need for additional adaptation.
Length of lamp to suit the space
Two housing sizes – 670 mm and 1270 mm – are available, allowing the luminaire to be optimally matched to the installation conditions and the specifics of explosive atmospheres (especially zone 1).
Electrical and photometric data


PrimeLine with a length of 670 mm, power of 24.6 W
PrimeLine with 670 mm length, 29.4 watts of power
PrimeLine with 670 mm length, 33.5 W output
PrimeLine with a length of 1276 mm, power of 44.2 W
PrimeLine with a length of 1276 mm, power of 54 W
PrimeLine with a length of 1276 mm, power 63.5 W
Parameters calculated for a temperature of 25oC, colour temperature 4000K, CRI > 80. Tolerance +/- 5%.
Klosz MROŻONY
Mocne, delikatnie rozproszone światło, bez efektu olśnienia
9 981 lm bez olśnienia
Inteligentny klosz minimalizuje ryzyko olśnienia i zmęczenia oczu.
Optymalny do użytku wewnątrz i na zewnątrz
Najlepsza równowaga pomiędzy intensywnością światła, a brakiem olśnienia.

Klosz MLECZNY
Rozwiązanie dedykowane do dużych pomieszczeń, w których często obecni są ludzie.
Najlepszy do użytku w pomieszczeniach
Brak olśnienia, brak zmęczenia oczu, bardzo dobre oddawanie barw
Idealny dla większych powierzchni
Specjalny klosz mocno rozprasza światło, nadając mu miękkość

Klosz TRANSPARENTNY
Mocne oświetlenie. Najlepsza wydajność. Najwyższa elastyczność.
Wysoka moc
Aż 10342 lm doskonale sprawdza się na zewnątrz oraz w wysokich pomieszczeniach.
Skieruj światło za pomocą 22 soczewek
Wyjątkowa możliwość swobodnej zmiany kierunku świecenia.

Dimensions and installation of Ex PrimeLine luminaire
| Fixture type. | L | L1 | B | 
|---|---|---|---|
| PrimeLine 60-********** | 670 | 400 | 173 | 
| PrimeLine 12-********** | 1276 | 800 | 173 | 
| Dimensions depend on mounting type. | H | B1 | 
|---|---|---|
| Ceiling bracket D18. | 119 | 157 | 
| Ceiling bracket D40. | 143,7 | 200 | 
| M8 eye bolt for suspended mounting. | 154,2 | — | 
| Pole mount bracket R50. | 156,2 | — | 
| Wall bracket K45 | 184,7 | — | 
| Ceiling bracket C | 153,4 | — | 
Dimensions in mm
Handle D18

D40 handle

R20 handle

R50 handle

Handle K45

Handle C

Photometry.
Download.
Instructions
PrimeLine – Ex ATEX industrial emergency lamp for zone 1 ready for any conditions
The new PrimeLine range of explosion-proof emergency lights under the central Ex ATEX battery has been designed as an efficient, reliable and versatile answer to the needs of industry. With a proven design, a wide range of options and an attractive price, PrimeLine will work well in both new installations and retrofitting of existing systems. Interoperability with Eaton central battery systems ensures seamless integration with central emergency power supply.
Optional emergency power supply from integrated battery – reliable for up to 3 hours
If, instead of being powered by a central battery, you decide to choose the option of an emergency explosion-proof lamp for zone 1 powered by an internal battery, the luminaire can operate in emergency mode for 1.5 or 3 hours, depending on the configuration. Versions suitable for sub-zero temperatures can be equipped with an integrated heater to stabilise battery conditions and ensure uninterrupted lighting in all conditions.
Lighting parameters that make a difference
The ATEX PrimeLine emergency lights feature above-average light output – one of the product’s strongest points:
- Shorter version: 4400 lumens at 125 lm/W
- Longer version: more than 8500 lumens at 145 lm/W
- Emergency variants with CB: 50% of basic light intensity
Suitable for harsh conditions – low and high temperatures
PrimeLine has been developed with extreme temperatures in mind. The emergency version with battery can operate even at -20°C and the standard models from -40°C to +50°C (with option up to +55°C). The versions with a central battery can withstand temperatures from -30°C to +50°C.
Certification at international level
Our PrimeLine emergency lamp powered by a central battery has full ATEX and IECEx certification, ensuring compliance with safety standards for explosive atmospheres worldwide. A CNBOP-approved version will also be available for the Polish market, which guarantees compliance with local regulations and formal requirements for emergency lighting.