Product features
High corrosion resistance
Hinged cover as option
Internal mounting plate as option
Cable glands plate as an option
Technical Data
Dimensions: please see details below
Certification: ATEX, IECEx
ATEX marking:
II 2 G Ex db eb ia/ib mb IIC/IIB T6…T4 Gb
II 2 D Ex tb IIIC T85°C… T135°C Db
IECEx marking:
Ex db eb ia/ib mb IIC/IIB T6…T4 Gb
Ex tb IIIC T85°C… T135°C
Material: Stainless Steel
Ambient temperature:
-50°C – +60°C (ATEX)
-50°C – +60°C (IECEx – up to +95°C for special “HT” models)
IP rating: IP66
Rated voltage: max 1000V
Rated current: max 160A
Price
Send us your request to receive a quotation.
Description

Construction
ATEX / IECEx enclosures of HCS1S series control stations are made of stainless steel AISI 316L. Stainless steel enclosures provide HARDO control stations with the highest resistance to corrosive agents. HCS1S series of control stations has following features:
body and cover are made of stainless steel AISI 316L.
stainless steel anti-loosening screws on cover.
polyuretane or silicone cover gasket.
stainless steel internal fixing screws.
enclosures are available in three different executions: cover fixed to body by antiloosening screws; cover jointed to body by hinges and locking keys; cover jointed to body by hinges and by anti-loosening screws. All systems provide the right pressure on gasket to grant the IP66 protection to the enclosure. When the cover is connected to the body by hinges, it may be possible to provide extra cable entries on each side wall by adding gland plates.
stainless steel internal mounting plates are available.
Function
Control Station HCS1S enclosures are often used for the following primary applications:
command and control stations
emergency call systems
instrument enclosures
breaker panels
toggle switches and changeover switches
lighting adjustments
terminal units
electrical enclosure
Battery holder
Control Station enclosures are available in a variety of sizes enabling you to choose an enclosure that is the best fit for your application. Control Station enclosures can be mounted together using specific flanges to form a big panel while retaining the IP protection of each individual enclosure. Starting at 90 mm in height, the enclosures can be outfitted with cover operators (pilot lights, push buttons, switches, etc.).
Dimensions





TYPE | A | B | C | D | E |
---|---|---|---|---|---|
HCS1S101210 | 100 | 120 | 100 | 150 | - |
HCS1S142013 | 140 | 200 | 130 | 170 | - |
HCS1S151510 | 150 | 150 | 100 | 180 | - |
HCS1S202016 | 200 | 200 | 160 | 230 | 160 |
HCS1S202713 | 200 | 270 | 130 | 230 | 230 |
HCS1S202716 | 200 | 270 | 160 | 230 | 230 |
HCS1S272713 | 270 | 270 | 130 | 300 | 230 |
HCS1S273513 | 270 | 350 | 130 | 300 | 310 |
HCS1S273516 | 270 | 350 | 160 | 300 | 310 |
HCS1S282816 | 280 | 280 | 160 | 310 | 240 |
HCS1S282827 | 280 | 280 | 270 | 310 | 240 |
HCS1S353516 | 350 | 350 | 160 | 380 | 310 |
HCS1S353520 | 350 | 350 | 200 | 380 | 310 |
HCS1S355016 | 350 | 500 | 160 | 380 | 460 |
HCS1S355020 | 350 | 500 | 200 | 380 | 460 |
HCS1S383816 | 380 | 380 | 160 | 410 | 340 |
HCS1S383820 | 380 | 380 | 200 | 410 | 340 |
HCS1S383827 | 380 | 380 | 270 | 410 | 340 |
HCS1S384516 | 380 | 450 | 160 | 410 | 410 |
HCS1S384520 | 380 | 450 | 200 | 410 | 410 |
HCS1S385716 | 380 | 570 | 160 | 410 | 530 |
HCS1S505016 | 500 | 500 | 160 | 530 | 460 |
HCS1S505020 | 500 | 500 | 200 | 530 | 460 |
HCS1S575716 | 570 | 570 | 160 | 600 | 530 |
HCS1S575720 | 570 | 570 | 200 | 600 | 530 |
HCS1S575730 | 570 | 570 | 300 | 600 | 530 |
HCS1S577620 | 570 | 760 | 200 | 600 | 720 |
HCS1S769520 | 760 | 950 | 200 | 790 | 910 |
Components
HCS1S series control stations can be fitted with a wide variety of certified components from leading global manufacturers. Among these components are pushbuttons, pilot and signal lamps, emergency mushroom head pushbuttons, circuit breakers, relays, isolator switches and measuring devices.
Push Buttons



Spring-return pushbutton units and spring-return double pushbuttons can be combined with various types of contact modules in order to provide many different combinations of NO and NC contacts. These units are available in different colours and, as an option, may be fitted with various marking labels.




Emergency Mushroom Head Pushbuttons



Spring return mushroom head pushbutton units, complete with one electrical contact module.
Push-pull emergency mushroom head pushbutton units (with or without key extraction), complete with one electrical contact module.
Turn-to-release emergency mushroom head pushbutton units complete with one electrical contact module.






Selector Switches



Stay-put or spring return key selector units complete with one electrical contact module.




Signal Lamps

Signal lamps approved for use in hazardous areas. They come complete with an LED unit designed for different voltages as per electrical circuit requirements. Signal lamps are available in different colors.

Signal Lamps with Button

Spring-return illuminated push button unit. Complete with LED unit, available in different voltages and with one electrical contact. Available with different combinations of NO and NC contacts. Available in different colours.

Potentiometers

Potentiometer unit with range of resistance values. The knob is provided with a large visual display.

Voltmeters, Ammeters, Miliammeters

The HVA (Harmonic Voltage Analysis) Voltmeter, Ammeter, Miliammeter units are available with a large number of measuring range options, scaled 2 or 5 times. The ammeter unit can make a direct measurement or be used in conjunction with current transformers and upon request, secondary current transformers. The ammeter has a working temperature range from -40°C to +60°C

Switch module 2 – Pole

Two separate pressing rods controlling a group of contacts each. One group or two groups of contacts can be controlled by different operation heads to have different functions.

Switch module 4 – Pole

Two separate metal pressing elements, controlling two group of contacts each. Two groups or four groups of contacts can be controlled by different operation heads to have different functions.

Protective Window

Pilot light window of thermoresistant glass sealed with auto-leveling silicone.

Circuit breakers

Circuit breakers are devices that shut off power flow when a short circuit occurs. They are designed to protect people in potentially explosive atmospheres and can be used with currents of 6, 10, 16, 20, 25, 32 or 40 amps, with residual currents of 10, 30, 100 and 300 milliamps.

Contactors Rated voltage 24 V / 240 V
Contactors are compact components for Ex e enclosures in Zones 1 and 2, and are durable and reliable for use in hazardous areas. All are easy to install, rugged and corrosion-resistant. The contactors are mounted in Ex e protected enclosures and can be used for a wide variety of applications.

Load Isolation Switches with Handle for currents up to 180 A

Load isolation switch module is certified and must be installed in an increased safety “Ex e” enclosure. It has good flame retardant performance and fast connect or breaking once the spring is tight to release. Wire terminals’ screws are made of stainless steel.
Cable Glands

Cable Glands are devices that are used to connect and fasten the end of an electrical cable to the target equipment. Cable Glands are used for all types of power, control, instrumentation, data and communications cables. There are cable glands for non-armoured and armoured cables. In addition to a wide range of cable glands other accessories like adaptors, reducers and stopping plugs are available.

ATEX control station made of stainless steel – advantages
Highly hygienic and easy to clean
Stainless steel control stations are also highly hygienic and easy to clean, making them suitable for use in the food and beverage industry. Stainless steel surfaces are smooth and non-porous which makes them resistant to bacteria and other pathogens. In addition, they can be easily cleaned and sanitized, which is crucial in industries where hygiene is critical.
High strength and robustness
Stainless steel control stations offer several advantages over other types of control stations, particularly in hazardous areas. One key advantage is their high strength and robustness. Stainless steel is a very strong material which means that control stations made from this material can withstand harsh environmental conditions and physical impacts better than other materials.
Long-lasting
Stainless steel control stations are highly durable and long-lasting. They can withstand impacts, vibrations and other types of mechanical stress which can help ensure reliable operation in harsh environments. In addition, stainless steel control stations are resistant to fire and explosions which is crucial in hazardous environments where these risks are present.
Summary
Overall, stainless steel control stations offer a durable, heat-resistant, corrosion-resistant, hygienic and visually appealing solution for controlling equipment in hazardous areas. Their high strength, temperature resistance and easy-to-clean surfaces make them ideal for a wide range of applications in industries such as chemical processing, oil and gas, marine, pharmaceutical, food and beverage and more.